System Integration Panel

The TA-2902-AC Series panels are designed to integrate the access control system and electronic architectural hardware, in a convenient location for commissioning and testing.

TA-2902-AC

Our pre-configured integration panels take theguesswork and finger pointing out of projects withmultiple suppliers of electrified door hardware, cardaccess and automatic door systems.
The cabinet is made from 18 gauge steel with acorrosion resistant enamel finish.
24 screw terminals allow the independenttermination of door hardware, access controlequipment and automatic door controls.
With a removable back-panel, labelled terminalsand multi-sized knock-outs the TA-2902-AC Serieswill benefit any system requiring integration.

 

TA-2902-AC1 Standard Card Access


System Components Integrated:

- Access Control System (Card or Fob)

- Lock Power Supply

- Electric Lock, Electric Exit Device, Strike or Maglock

- Door Position Switch

- Request To Exit Device


Integrated System Operation:

- Door is normally closed and locked.

- Access by presentation of a valid Card or Fob will causedoor to unlock (programmable time through accesscontrol software by others, or optional).

- Exit is free at all times.

- Door will lock upon loss of main power (or fire alarmwhen required).

- Door position and request to exit signals are available formonitoring by access control system at TA-2902-AC terminals.

TA-2902-AC2 Card Access w/Power Door Operator


System Components Integrated:


- Access Control System (Card or Fob)

- Lock Power Supply- Powered Door Operators- Electric Lock, Electric Exit Device, Strike or Maglock- Door Position Switch

- Request To Exit Device


Integrated System Operation:


- Door is normally closed and locked.

- Access by presentation of a valid Card or Fob will causedoor to unlock and enable exterior door operator switch,so door can be opened manually or by activation ofexterior door operator switch (programmable time through access control software by others, or optional).

- Exit is free at all times. Activation of interior dooroperator switch will cause door to unlock and open.

- Door will lock upon loss of main power (or fire alarm when required).

- Door position and request to exit signals are available for

monitoring by access control system at TA-2902-AC terminals.