Operation
-Door is normally closed and unlocked.
-The door can be manually opened or automatically opened by waving a hand in front of the exterior handicap touchless actuator.
-Once a user has entered the washroom they can lock the door waving a hand in front of the touchless "lock" switch which will lock the electric strike, disable outside handicap actuator, and prevent automatic door operator from opening door. The LED indicators on all touchless switches will change from green to red, indicating that the washroom is occupied and locked.
-Exit is always free by inside handicap touchless actuator or by opening door manually; LED indicators will change from red to green, indicating that the washroom is vacant, and unlocked.
-In case of emergency the user can push the TA-3241-EP-LED push button which will activate visual and audible signals inside and outside of the washroom. Alarm is reset at the TA-3241-EP-LED switch.
-Emergency access into washroom by using key in outside lever handle.
-Optional connection to a card access system is included for secure applications and simple integration.
|
Kit includes:
1-TA-2902-UWCTL Washroom controller
1-TA-2501 Power supply
2-TA-2707 AV Indicator
1-TA-3241-EPLED Emergency push button
1-TA-EXS-PCFAC Emergency sign
1-TA-4103 Door position switch
1-DH X-86F-26D Lever storeroom lock
1-TA-5642 Electric strike
1-TA-DTAO019-1 Low energy door operator
2-TA-8162HCWTO Touchless switch
1-TA-3271-WTL Touchless Lock switch
|